22.03.2012 - Version 1.5.1

  • Improvement: More precise signal course display in Scope function
  • New: Filename of bitmap or raw data is shown while file is written
  • New: In the Scope function, the current settings of Zoom and Delay are stored in EEPROM when "Save&OK" is executed in Setting menu
  • Bugfix: Memory was not totally freed up after writing a bitmap to the internal memory card (~550 bytes for each saved picture)

13.03.2012 - Version 1.5.0

New features:

  • Tracing of incoming CAN traffic to internal memory card
  • Playback of previously recorded traces to connected CAN bus
  • ID ranges for symbols implemented (new version of configuration tool PCAN-Diag Editor for Windows needed)

Changes:

  • Scope: grid is only redrawn if necessary
  • Scope: trigger level is only shown when edge trigger is activated
  • Symbols: limit of 50 signals per message removed
  • Symbols: improved memory management

Bug fixes:

  • D-Sub voltage ranges: negative min/max values could not be used
  • Scope: no triggering in Run mode if the Single trigger wasn't used before

11.10.2011 - Version 1.4.7

Improvements:

  • Adjustments for PCAN-Diag devices with Low-speed CAN or Single-wire CAN transceiver
  • Calibration of the measurement facility for the High-speed CAN termination; status is indicated next to the measuring value: "cal. OK" (green) or "not cal" (red, please contact our support team for calibration)
  • If a transmit list only contains a single CAN message, an edit screen for this message can be directly invoked from the "Transmit Messages" screen. Changes of the message's properties affect directly
  • New mask for editing a CAN message; CAN data can be entered as decimal, hexadecimal, or in a binary field
  • Internal pull-up resistor for the BNC connection disabled by default and activated during use of the oscilloscope function
  • CSV files exported by the oscilloscope function now additionally contain the set bitrate and the date and time
  • Receive messages: Message overrun counter added

Bug fixes:

  • Improvement of message reception reduces possibility of message overruns
  • Measurement of CAN termination returned values being 0.6 % too low

31.05.2011 - Version 1.4.6

Improvement:

  • Scope: CAN frames are automatically decoded after each trigger

Changes:

  • CAN differential signal renamed from CAN(H-L) to CAN-Diff
  • Number of Enums increased from 250 to 400
  • Shows "Saving bitmap ..." while writing to memory card

Bug fixes:

  • Import of a new project corrupted internal memory if too many transmit lists were defined
  • Memory corruption if Enums were used (device might crash)
  • Differential scope signal (blue) was drawn outside screen area
  • Saving of scope settings did not work
  • Import of project did not load settings for CAN trigger ID/format/type
  • New bug since V1.4.5: saving of bitmaps was not possible
  • Device Settings > User CAN bitrates: when BTR was set to 0x0000, SP and SJW was displayed as 0 immediately (update problem)

Version 1.4.5

Improvements:

  • Scope can display CAN-H and CAN-L as a differential signal
  • Device Settings: Up to 8 User Bitrates can be defined
  • Scope signal is shown in red in case that the ADC upper or lower limit is reached

Change:

  • Number of symbol messages and variables increased

Version 1.4.4

Improvements:

  • Symbols can be sorted by ID, Name, and Count
  • Symbols are shown in RED in case of a Message Timeout

Bug fix:

  • Selected list item has a different color

Version 1.4.3

  • Improvement: Bootloader update possible via firmware update (special bootloader file required)
  • Several bug fixes concerning the display of symbols

Version 1.4.2

  • Bug fix: '°'-Character can be used in Symbol names and units
  • Folder in Root directoy renamed from "PCANDiag" to "PCAN-Diag"
  • First official release version

Version 1.4.1

  • "Profiles" removed and replaced by "Projects"
  • At module startup it is checked whether the currently active project has been updated in the memory card. If so, the project is loaded from memory card and copy in eeprom is updated
  • Several optimizations in the procesing of symbols

Version 1.4.0

  • Separate Firmware for memory card support/non memory card support
  • Profiles contain all configurations (Settings, Scope + Transmitlists)
  • Added ok/save&ok/exit for menu "Manage Transmit List"
  • Changed static memory for transmit lists into dynamic memory allocation to increase memory for heap (224k heap required for firmware update)
  • Changed static memory for scope sample buffer into dynamic memory allocation
  • Bug fix: Display current level of submenus in topline of screen correctly

 

 
微控制器硬件
PCAN-MicroMod
PCAN-MicroMod評(píng)估板套裝
PCAN-MicroMod模擬1 & 2
PCAN-MicroMod數(shù)字1 & 2
PCAN-MicroMod混合1 & 2
PCAN-MicroMod混合3
PCAN-RS-232
PCAN-MIO
MU-Thermocouple1 CAN
PCAN-Router
PCAN-Router Pro
PCAN-GPRS Link
PCAN-Diag

CAN總線(xiàn)診斷儀
PDF下載


Email 博客 論壇 點(diǎn)擊發(fā)送消息給我

020-3874 3032; 13434369840 | sales@hkaco.com | 廣州虹科電子科技有限公司 | 版權(quán)所有 | 廣州市科學(xué)城神舟路18號(hào)潤(rùn)慧科技園C棟6層

  產(chǎn)品系列
     硬件
CAN總線(xiàn)接口
CAN總線(xiàn)轉(zhuǎn)換器系列
微控制器硬件系列
     軟件
     附件
  服務(wù)項(xiàng)目
  新聞和活動(dòng)
  技術(shù)支持
全部產(chǎn)品系列 > 工業(yè)通訊 > Peak System > 產(chǎn)品 > 硬件系列 > 診斷和教學(xué)
主站蜘蛛池模板: 成人精品一级毛片| 色播欧美| 日韩在线www| 一级特黄特色aa大片| 96精品免费视频大全| 91无套极品外围在线播放| jiucao在线看片www| 永久免费看电视网站| 亚洲b| 精品国产欧美精品v| 丁香五婷婷| 美女国产精品福利视频| 国产免费一区不卡在线| 免费的毛片视频| 欧美成人免费午夜全| 亚洲国产成人久久99精品| 91国语精品自产拍在线观看性色| 日日干夜夜爱| 曰曰碰天天碰国产| 亚洲欧美综合人成野草| 成年美女黄网站色大片免费看| 欧美成人性生活视频| 国产午夜精品一二区理论影院| 国产精品成人麻豆专区| 黄网址在线永久免费观看| 不卡久久| 丰满大乳乳液| 国产欧美亚洲精品第二区首页| 玖玖国产在线观看| 免费vip影院| 欧美日韩国产在线| 日本一二三精品黑人区| 天天鲁一鲁| 思思九九| 天堂激情| 视频在线观看大片| 午夜国产精品免费观看| 亚洲精品国产一区二区三区在 | 久久亚洲综合| 妞干网免费在线| 女女同性一区二区三区四区|