22.03.2012 - Version 1.5.1

  • Improvement: More precise signal course display in Scope function
  • New: Filename of bitmap or raw data is shown while file is written
  • New: In the Scope function, the current settings of Zoom and Delay are stored in EEPROM when "Save&OK" is executed in Setting menu
  • Bugfix: Memory was not totally freed up after writing a bitmap to the internal memory card (~550 bytes for each saved picture)

13.03.2012 - Version 1.5.0

New features:

  • Tracing of incoming CAN traffic to internal memory card
  • Playback of previously recorded traces to connected CAN bus
  • ID ranges for symbols implemented (new version of configuration tool PCAN-Diag Editor for Windows needed)

Changes:

  • Scope: grid is only redrawn if necessary
  • Scope: trigger level is only shown when edge trigger is activated
  • Symbols: limit of 50 signals per message removed
  • Symbols: improved memory management

Bug fixes:

  • D-Sub voltage ranges: negative min/max values could not be used
  • Scope: no triggering in Run mode if the Single trigger wasn't used before

11.10.2011 - Version 1.4.7

Improvements:

  • Adjustments for PCAN-Diag devices with Low-speed CAN or Single-wire CAN transceiver
  • Calibration of the measurement facility for the High-speed CAN termination; status is indicated next to the measuring value: "cal. OK" (green) or "not cal" (red, please contact our support team for calibration)
  • If a transmit list only contains a single CAN message, an edit screen for this message can be directly invoked from the "Transmit Messages" screen. Changes of the message's properties affect directly
  • New mask for editing a CAN message; CAN data can be entered as decimal, hexadecimal, or in a binary field
  • Internal pull-up resistor for the BNC connection disabled by default and activated during use of the oscilloscope function
  • CSV files exported by the oscilloscope function now additionally contain the set bitrate and the date and time
  • Receive messages: Message overrun counter added

Bug fixes:

  • Improvement of message reception reduces possibility of message overruns
  • Measurement of CAN termination returned values being 0.6 % too low

31.05.2011 - Version 1.4.6

Improvement:

  • Scope: CAN frames are automatically decoded after each trigger

Changes:

  • CAN differential signal renamed from CAN(H-L) to CAN-Diff
  • Number of Enums increased from 250 to 400
  • Shows "Saving bitmap ..." while writing to memory card

Bug fixes:

  • Import of a new project corrupted internal memory if too many transmit lists were defined
  • Memory corruption if Enums were used (device might crash)
  • Differential scope signal (blue) was drawn outside screen area
  • Saving of scope settings did not work
  • Import of project did not load settings for CAN trigger ID/format/type
  • New bug since V1.4.5: saving of bitmaps was not possible
  • Device Settings > User CAN bitrates: when BTR was set to 0x0000, SP and SJW was displayed as 0 immediately (update problem)

Version 1.4.5

Improvements:

  • Scope can display CAN-H and CAN-L as a differential signal
  • Device Settings: Up to 8 User Bitrates can be defined
  • Scope signal is shown in red in case that the ADC upper or lower limit is reached

Change:

  • Number of symbol messages and variables increased

Version 1.4.4

Improvements:

  • Symbols can be sorted by ID, Name, and Count
  • Symbols are shown in RED in case of a Message Timeout

Bug fix:

  • Selected list item has a different color

Version 1.4.3

  • Improvement: Bootloader update possible via firmware update (special bootloader file required)
  • Several bug fixes concerning the display of symbols

Version 1.4.2

  • Bug fix: '°'-Character can be used in Symbol names and units
  • Folder in Root directoy renamed from "PCANDiag" to "PCAN-Diag"
  • First official release version

Version 1.4.1

  • "Profiles" removed and replaced by "Projects"
  • At module startup it is checked whether the currently active project has been updated in the memory card. If so, the project is loaded from memory card and copy in eeprom is updated
  • Several optimizations in the procesing of symbols

Version 1.4.0

  • Separate Firmware for memory card support/non memory card support
  • Profiles contain all configurations (Settings, Scope + Transmitlists)
  • Added ok/save&ok/exit for menu "Manage Transmit List"
  • Changed static memory for transmit lists into dynamic memory allocation to increase memory for heap (224k heap required for firmware update)
  • Changed static memory for scope sample buffer into dynamic memory allocation
  • Bug fix: Display current level of submenus in topline of screen correctly

 

 
微控制器硬件
PCAN-MicroMod
PCAN-MicroMod評(píng)估板套裝
PCAN-MicroMod模擬1 & 2
PCAN-MicroMod數(shù)字1 & 2
PCAN-MicroMod混合1 & 2
PCAN-MicroMod混合3
PCAN-RS-232
PCAN-MIO
MU-Thermocouple1 CAN
PCAN-Router
PCAN-Router Pro
PCAN-GPRS Link
PCAN-Diag

CAN總線(xiàn)診斷儀
PDF下載


Email 博客 論壇 點(diǎn)擊發(fā)送消息給我

020-3874 3032; 13434369840 | sales@hkaco.com | 廣州虹科電子科技有限公司 | 版權(quán)所有 | 廣州市科學(xué)城神舟路18號(hào)潤(rùn)慧科技園C棟6層

  產(chǎn)品系列
     硬件
CAN總線(xiàn)接口
CAN總線(xiàn)轉(zhuǎn)換器系列
微控制器硬件系列
     軟件
     附件
  服務(wù)項(xiàng)目
  新聞和活動(dòng)
  技術(shù)支持
全部產(chǎn)品系列 > 工業(yè)通訊 > Peak System > 產(chǎn)品 > 硬件系列 > 診斷和教學(xué)
主站蜘蛛池模板: 国产亚洲情侣一区二区无| 深夜国产一区二区三区在线看 | 青青青久热国产精品视频| 性美国xxxxx免费| 欧美精品中出| 亚洲综合第一| 九九在线免费观看视频| 丝袜制服中文字幕| 全免费一级午夜毛片| 欧美精品在线一区二区三区| 怡红院综合网| 黄的三级在线播放| 国产成人麻豆tv在线观看| 在线亚洲色图| 曰本在线网| 在线观看免费高清激情爱爱| 欧美r级毛片在线播放| 国产不卡一区| 国产福利一区二区在线观看| 国产成人亚洲影视在线| 久久99国产亚洲高清| 欧美日韩国产一区二区三区播放 | 三级短视频| 日韩一区二区免费视频| 欧美一级做一a做片性视频| 国产精品一页| 娇喘嗯嗯~轻点啊视频福利 | 欧美草逼片| 国产成人高清亚洲一区91| 国产精品新婚门| 狠狠亚洲婷婷综合色香五 | 欧美综合另类| 午夜精品亚洲| 亚洲精品第一| 亚洲免费观看视频| 亚洲精品午夜aaa级久久久久| 91插插插视频| 521香蕉在线观看视频| 国产一级片儿| 国产黄色免费网站| 国产精品女人在线观看|